202206023I : PCA9509P Data Sheet Max Vih Change

Changed PCA9509P max Vih specification to clearly indicate A Port B Port and Enable pins are over voltage tolerant to 5.5V. There is no change to device or test coverage. This is only a clarification to current documentation. Updated data sheet posted on NXP.com www.nxp.com/docs/en/data-sheet/PCA9509P.pdf

PCNタイプ カテゴリー変更 発行日 有効期限
Customer Information Notification Electrical spec./Test coverage 29-Jul-2022 30-Jul-2022

変更理由

PCA9509P recommended static characteristics Table 6 max Vih specification for A Port B Port and Enable are the normal value if pull ups are connected to device supply. Table 6 max Vih voltage is being changed to clearly show the pins are over voltage tolerant. Port A from Vcc(A) to 5.5V Port B from Vcc(B) to 5.5V and Enable from Vcc(B) to 5.5V.

予想される影響

データシートの改訂: A new datasheet will be issued

対象品番

品番/12NC 最終購入日 最終納品日 交換品番
PCA9509PDP,118
(935297955118)
- - -
PCA9509PGM,125
(935297954125)
- - -